CUE21浊度计的经常使用调试指南 (cue21浊度仪标定失败怎么处理)

宣布于:2007-12-0413:50:00楼主 CUE21仪表经常使用于测量浊度比拟低的场所:IntroductionandConfigurationofTurbimaxCUE21 引见和组态 Introduction 仪表引见 nTheturbimaxCUE21processturbidimetershavebeendesignedforon-linemeasurementoftheturbidityofprocesswateranddrinkingwater.TheinfraredlightinstrumentCUE21,meetsthedesigncriteriaonturbiditymeasurementspecifiedinISO7027andDIN27027浊度仪CUE21设计用来启动在线测量工艺水和饮用水中的浊度值,CUE21是红内线光源仪表,在浊度测量上满足ISO7027和DIN27027规范 Scopeofdelivery 到货范畴 n1turbimaxCUE21turbidimeterCUE21浊度计一台n1fieldterminalbox接线盒一个n1flowthroughassembly流通组件1套n1desiccantpack枯燥剂包一个n1cuvette(singlepack)玻璃测量杯一个(单包装)n1tubingkitincluding(管衔接件包含以下)-1shutoffclamp截断夹1个-1backpressurevalve背压阀1个-2connectingtubeswithfittingsforflowthroughassembly带流通组件的衔接收2个-1drainventscrew(usedinpressurizedsystems)放空螺钉用于压力系统 Installationintroduction 装置说明nTurbimaxCUE21isdesignedforwallmounting.CUE21设计用于墙体装置nOperatingtemperature0—50ºC仪表上班温度0—50ºCnLeaveafreeareaofapprox0.2mabovetheinstrument.thisensureenoughroomforcalibrationandcuvettemaintenance仪表上方保障有0.2M的空间,保障有足够的空间启动校验和保养nMounttheinstrumentascloseaspossibletothesamplingpointtoensureaquickresponsetime(within2—3m)装置仪表要尽量接近测量点(普通在2-3M) Desiccantpouch 枯燥剂 TurbimaxCUE21isequippedwithacontinuousvaporpurgesystem,Areplaceabledesiccantpouchinthelowerportionoftheinstrumentdriestheair.Systemheatisusedtowarmtheair,AfaninsidetheinstrumentcontinuouslycirculatesheatedairaroundtheopticalwellandtheflowthroughcuvetteCUE21带有延续的水蒸汽污染系统,仪表外部的最上方放有可以改换的枯燥剂包用来枯燥空气,系统加热用来加热空气。仪表外部的风扇使热空气在光源器件和流量测量杯间启动延续的循环。 Installingthedesiccantpouch 枯燥剂的装置 nUnscrewthefourcornerthumbscrews关上仪表上方的四个螺钉nRemovetheelectronicshalfoftheinstrument将仪表外部的电子器件局部取出nOpenthebagprotectingthedesiccantpouchandinstallitwiththehumidityindicatorinthedesiccanttrayassembly(oncethebagisopened,installthedesiccantpouchimmediatelytopreventprematuredegradationofthedesiccant关上枯燥剂包全袋,将湿度批示标签和枯燥剂一同放入枯燥剂托盘附件(一旦这个包全枯燥剂的袋子关上,尽快的装置枯燥剂以防止枯燥剂过早的失效)nReplacetheelectronichalfoftheinstrumentandtightenthefourcornerthumbscrewagain将电子部件放回仪表外部,拧紧4个螺钉Note:Topreventprematuresaturationofthedesiccant,itisrecommendedtoKeepthemeasurementchambercoveratanytime留意:为了防止枯燥剂过早的饱和,倡导任何时刻保障测量仓的盖子要封锁. 对于装置图形参见说明书 测量杯 nTheultrasoniccuvettemustbecompletelydrybeforeitisinsertedintothesensor,ifthereisanyvisiblemoisturepresentonthecuvetteortransducer,thereisgreatriskofdamagingthesensorelectronicsandtransducer测量杯在拔出传感器前要保障它是齐全枯燥的,假设测量杯或传感器上有任何可见的湿润水珠存在,传感器的电子器件和传感器将会有损坏的风险。 Installingthecuvette 测量杯的装置 nCheckthatthecuvetteiscleanandfreeofscratchesormarks审核测量杯能否清洁,要保障没有滑痕nRemovetheflowheadofturbimaxCUE21关上CUE21的流量头(顺时针关上流量头)nCarefullyscrewthecuvetteintoth 收藏 约请回答 回复楼主 投诉

本文原创来源:电气TV网,欢迎收藏本网址,收藏不迷路哦!

相关阅读

添加新评论